Meriam M334 4-20 Milliamp Loop Calibrator Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Werkzeug Meriam M334 4-20 Milliamp Loop Calibrator herunter. Meriam M334 4-20 Milliamp Loop Calibrator User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 8
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Product Description
EASY TO USE
With the Meriam Model M334 you can check,
calibrate and measure all your current signal
instruments in a 4 to 20 milliamp DC loop. It can
be used at any access point in your loop. Source &
Read 0.00 to 24.00 mA, Simulate a 2 Wire
Transmitter or use the Meriam Model M334 to
simultaneously power your 2 Wire Transmitter and
measure its output. When desired the Meriam
Model M334 can display current in milliamps or
percent of 4 to 20.
SOURCE MILLIAMPS
Calibrate recorders, digital indicators, stroke valves
or any instruments that get their input from a 4 to
20 mA loop. Easily set any value quickly to within
0.01 mA with the adjustable digital potentiometer
DIAL or use preset 4.00 mA (0.0%) and 20.00
mA (100.0%) EZ-CHECK™ settings.
RECALL OUTPUT SETTINGS
The EZ CHECK™ switch provides rapid checking
of 4.00, 20.00 and any convenient third point
between 0.00 to 24.00 mA.
CALIBRATE USING LOOP POWER
Check loop wiring and receivers by using the
Meriam Model M334 in place of a 2 Wire
transmitter. Simulate a changing process input to
check loop response and control settings. The
Meriam Model M334 uses any loop power from 2
to 100V DC.
READ LOOP CURRENT
Check controller outputs or measure the milliamp signal anywhere in the loop. The Meriam
Model M334 measures 0.00 to 52.00 mA signals with greater accuracy than a typical multimeter.
The Meriam Model M334 can be easily switched to display milliamps or percent of 4 to 20.
POWER & MEASURE 2 WIRE TRANSMITTERS
The Meriam Model M334 can simultaneously output 24V DC to power any and all devices in a
process loop using the internal batteries and the internal switching power supply, while
measuring the output of a 2 Wire Transmitter and any other loop devices. This is handy for
checking the functionality of transmitters in the field or on the bench.
READ DC VOLTS
The Meriam Model M334 can measure from -99.99 to +99.99 VDC with 10mV resolution. Use it
to check loop power supplies, I/V converters, chart recorders, 1 to 5 Volt signals, and any other
voltages within this range making it unnecessary to carry an additional multimeter.
Meriam Model M334
4-20 mA Loop Calibrator
Operating Instructions
Meriam Model M334
4-20 mA Loop Calibrator
Operating Instructions
Meriam Process Technologies
10920 Madison Ave. • Cleveland, OH 44102 Tel: 216.281.1100 • Fax: 216.281.0228 • [email protected] • www.meriam.com
Copyright © 2008 All rights reserved • M334-9002 - 22 July 2008

Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - Meriam Model M334

Product Description• EASY TO USEWith the Meriam Model M334 you can check, calibrate and measure all your current signal instruments in a 4 to 20 mill

Seite 2 - Meriam Process Technologies

q POWER SWITCHSelect “mA” to display and calibrate in milliamps.Select “% 4 to 20 mA” to display and calibrate in percent. Select “READ VDC” to

Seite 3 - Reading Milliamp Outputs

mA OUT, % OUT (Percent of 4 to 20 mA)Choose this function to provide an output from 0.00 to 24.00 milliamps. The compliance voltage is a nominal 24 VD

Seite 4 - Simulate 2-Wire Transmitters

2 Wire mA, 2 Wire % (Percent of 4 to 20 mA)Choose this function to simulate a 2 Wire Transmitter output from 0.00 to 24.00 milliamps. Operates in loop

Seite 5 - Application Notes

READ VChoose this function to measure from -99.99 to +99.99V DC.1) Select “READ VDC” with slide switch q.2) Connect the red (+) and black (-)

Seite 6 - Accessories

AccessoriesAC ADAPTOR (200 to 240 VAC) Part No. 020-0100AC ADAPTOR (100 to 120 VAC) Part No. 020-0101Ni-MH 1 Hour Charger w/4 Ni-MH AA Batte

Seite 7 - Meriam M334 Specifications

GeneralOperating Temperature Range -20 to 60 °C (-5 to 140 °F)Storage Temperature Range -30 to 60 °C (-22 to 140 °F)Relative Humidity Range 10 % ≤RH ≤

Seite 8 - Additional Information

Source/Power & Measure Two Wire TransmittersM334 Ranges and Resolution0.00 to 24.00 mA Full Span or -25.0 to 125.0% of 4-20 mAAccuracyEZ Check(s)

Kommentare zu diesen Handbüchern

Keine Kommentare